PFR-100 Series Fanless Multi-Range D.C. Power Supply

Category: ,
Tags:

The PFR-100 series, a small and high-performance programmable D.C. power supply, adopts natural convection design to dissipate heat. The fanless structure allows users to focus on their experiments and tests in a quiet environment. Fanless power supply will not suck in dust and foreign objects, therefore, PFR-100 series has a longer life cycle compared with that of power supplies with fan.

The PFR-100 series is a power supply with a five-fold rated power that allows users to self-define voltage and current under rated power conditions so as to satisfy them with wider voltage and current operational ranges. PFR-100 series, with rated 100W, provides two models: PFR-100L- maximum output voltage of 50V (at 2A) or maximum output current of 10A (at 10V); PFR-100M maximum output voltage of 250V (at 0.4A) or maximum output current of 2A (at 50V).

 

 

The PFR-100 series provides front and rear panel output terminals. The front panel output terminal helps users shorten test lead replacement time while conducting adjustment on front panel’s function keys. The rear panel output terminal facilitates an easy wiring operation for rackmount assembly. 3U height, 70mm width and 2.5KG in weight have greatly elevated PFR-100 series portability. Furthermore, the multi-drop mode allows users to control up to 31 PFR-100 series without using switch/Hub that help users save the equipment cost.

 

More detail, please follow the PFR-100 Brochure.

  • Constant Power Output for 5 Times Multi-range(V&I) Operation
  • Natural Convection Cooling Design (Fanless Structure)
  • Preset Memory Function
  • Output ON/OFF Delay Function
  • CV, CC Priority Mode
  • Adjustable Slew Rate For Voltage and Current
  • Bleeder Circuit Control
  • Protections: OVP, OCP, AC FAIL and OTP
  • Support Front and Rear Panel Output
  • Built-in USB, RS-232/485 and LAN Interface; Optional GPIB
  • Web Server Monitoring and Control
  • External Analog Control and Monitor Function
  • Remote Sensing Function

The specifications apply when the PFR-100 is powered on for at least 30 minutes.

Model PFR-100L PFR-100M
OUTPUT RATING

Rated Output Voltage: 50V

Rated Output Current: 10A

Rated Output Power: 100W

Rated Output Voltage: 250V

Rated Output Current: 2A

Rated Output Power: 100W

REGULATION (CV)

Load Regulation: 10mV

Line Regulation: 3mV

Load Regulation: 33mV

Line Regulation: 5mV

REGULATION (CC)

Load Regulation: 10mA

Line Regulation: 8mA

Load Regulation: 3.2mA

Line Regulation: 1.2mA

RIPPLE & NOISE

Vp-p: 50mV

Vr.m.s.: 4mV

A r.m.s.: 10mA

Vp-p: 150mV

Vr.m.s.: 15mV

A r.m.s.: 2mA

PROGRAMMING ACCURACY

Voltage: 0.1% of setting + 40mV

Current: 0.2% of setting + 20mA

Voltage: 0.1% of setting + 200mV

Current: 0.2% of setting + 2mA

MEASUREMENT ACCURACY

Voltage: 0.1% of reading + 40mV

Current: 0.2% of reading + 20mA

Voltage: 0.1% of reading + 200mV

Current: 0.2% of reading + 2mA

RESPONSE TIME

Rise Time: 50ms

Fall Time: 100ms

Transient Response Time: 1.5ms (Rated load)

Rise Time: 200ms

Fall Time: 300ms

Transient Response Time: 2ms (No load)

PROGRAMMING RESOLUTION

Voltage: 2mV

Current: 1mA

Voltage: 10mV

Current: 0.1mA

MEASUREMENT RESOLUTION

Voltage: 2mV

Current: 1mA

Voltage: 10mV

Current: 0.1mA

PROTECTION FUNCTION

Over Voltage Protection (OVP)

Over Current Protection (OCP)

Under Voltage Limit (UVL)

Over Temperature Protection (OTP)

Low AC Input Protection (AC-Fail)

Power Limit (Power Limit)

Setting Range: 5~55V (OVP)

Setting Range: 1~11A (OCP)

Setting Range: 0~52.5V (UVL)

Turn the output off (OTP)

Turn the output off (AC-Fail)

Turn the output off (Power Limit)

ENVIRONMENT CONDITION

Operating Temperature: 0°C to 40°C

Storage Temperature: -20°C to 70°C

Operating Humidity: 20% to 80% RH; No condensation

Storage Humidity: 20% to 85% RH; No condensation

OTHER Analog Control Yes
Interface

USB, RS-232/RS-485; Factory option: LAN/GPIB

AC Input: 85~265VAC, 47~63Hz, single phase

DIMENSIONS & WEIGHT 70(W)x124(H)x300(D)mm; Approx. 2.5kg

Notes:

  • *1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load.
  • *2: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.
  • *3: Measure with JEITA RC-9131B (1:1) probe
  • *4: Measurement frequency bandwidth is 10Hz to 20MHz.
  • *5: Measurement frequency bandwidth is 5Hz to 1MHz.
  • *6: From 10%~90% of rated output voltage, with rated resistive load.
  • *7: From 90%~10% of rated output voltage, with rated resistive load.
  • *8: Time for output voltage to recover within 0.1% + 10mV of its rated output for a load change from 50 to 100% of its rated output current.
  • *9: For load voltage change, equal to the unit voltage rating, constant input voltage.

Standard Accessories
CD (User Manual, Programming manual) x 1, Power cord x 1
GTL-134 test lead x 1, Accessory packages,
GTL-104A test lead & PFR-001 accessory kit (for PFR-100L only)
GTL-105A test lead & PFR-002 accessory kit (for PFR-100M only)

Option (factory installed)

PFR-GPIB: GPIB interface

Accessory Code Description
GTL-258 GPIB Cable, 2000mm
PSU-232 RS-232 Cable with DB9 Connector Kit.
PSU-485 RS-485 Cable with DB9 Connector Kit.
GTL-246 USB Cable (USB 2.0 Type A-TypeB Cable)
GRA-431-J-100 Rack mount adapter (JIS) with AC 100V
GRA-431-J-200 Rack mount adapter (JIS) with AC 200V
GRA-431-E-100 Rack mount adapter (EIA) with AC 100V
GRA-431-E-200 Rack mount adapter (EIA) with AC 200V
GTL-259 RS232 CABLE DB9F TO RJ45, 2M ,PFR OPT
GTL-260 RS485 CABLE DB9F TO RJ45, 2M ,PFR/PSU OPT
GTL-261 SERIAL MASTER CABLE+TERMINATOR ,0.5M ,PFR/PSU
GTL-262 SERIAL SLAVE CABLE, 0.5M ,PFR OPT
Ask for a Quote!